Specifications
Phone Standards Detected
IS-41 Analog(AMPS), IS-95 (CDMA), IS-136 (D-AMPS /TDMA ), Motorola iDEN systems (both Connect and Dispatch), GSM850. GSM900, GSM1800 and GSM1900
Frequency Sweep
The CPD186 searches for mobile phone activity from 700MHz 2500MHz.
Advanced digital filters reject signals not conforming to the above mobile phone standards.
Detection Method
Pulse envelope demodulation with Digital Signal Processing.
Unique detection algorithms prevent false alarms and allow strong signals to be picked up and weaker signals suppressed.
Battery Life
Typically 180-200* hours of operation
* this figure allows for several alarm conditions per day. If the vibration alarm is allowed to function for long periods this will impact battery life.
Auto-Power Off
The unit automatically powers itself off after 12 hours.
LED Indications
Typically 80 hours' operation. Auto power-off after 12 hours.
Low battery indicates that the 2x LR1 / N cells should
be replaced.
Bargraph
The 5 segment bar graph indicates the presence of a mobile phone and the approximate range to the source of the transmissions. The segments are colour coded for easy identification in low light situations. Each of the LEDs are used as Active indications depending on the sensitivity switch setting as well as showing RF activity. Flashing LEDs indicate a digital phone signal and its receive strength detected by the CPD186
The bargraph is also used to display Analog transmissions as a column of lights. Analog indications can be displayed simultaneously with the indication and strength of an active digital cellphone.
Low Batt
Indicates that battery voltage is low and that the batteries should be replaced.
On / Reset Switch
This switch provides multiple functions.
A single press will activate the unit.
Once an alarm condition has commenced and vibrator is functioning, the vibrator can be temporarily silenced by a single press during the alarm. The vibrator is automatically re-instated when another alarm condition is detected.
To move to next range press and hold the button until the next LED starts flashing, then release the button. If the button is continually pressed the unit will cycled through all the 5 range settings and then switch OFF.
Internal Switches
DIP switches on the circuit board allow the user to select the following
| Switch
1 |
Function |
| ON |
Display set to increment in 3dB steps |
| OFF |
Display set to increment in 2dB steps |
| Switch
2 |
Function |
| ON |
n/a |
| OFF |
n/a |
Physical
Size 85 x 46 x 16mm (length x width x depth)
Weight 59 grams (including batteries)
Battery 2 x N cells
Material ABS |